CB Series RKC temperature controller:
Input a)Thermocouple (TC)K ,J, E ,T, R, S, B, U, L, N, PL2, W5He/W26Reb)thermal resistance (RTD):Pt100 JPT100c)Analog Input :DCO-5V.DC1-5V.DCO-20mA*.DC4-20mA*#Set a 250Ω resistance between input terminals.Orecision of input display:+(0.3%+1 of SV)Input range:refer to input range listSample rate:0.5secDeviation-1999-9999oC[*F ] or -199.9-999.9oC[*F ](TemperatureInput)+Complete measuring range (Voltage /Current Input) Set range a) SV: equal to temperature rangeb) heating side proportion(P):1- measuring range or 0.1- measuring range (TemperatureInput)*10.1-100% of measuring range (Analog Input )c) cooling side proportion(PC):heating side proportion1-1000%d) integration time (I):1-3600sec*2 e) rate time (D):1-3600sec*3f) ARW :1-100%*4 of proportiong) heating side proportion cycle 1-100sec*5 h) cooling side proportion cycle 1-100sec*6 i) non-sensitive zone -10¡ã-10 or -10.0 -+10oC[*F](Temperature Input)-10-+10.0% of measuring range(Voltage /Current Input)*7 *11.If the proportion is oC[*F ]it is ON-OFFmotion *2.If integration time is 0sec,PD is available *3.If rate time is 0sec, PI is available*4.If set limit motion as 0%, the motion is OFF*5.cycle si not needed to set when it is current output. *6.cycle si not needed to set when it is current output. Control actionPID control(ON-OFF.P.PI.PD control) a)Autotuning algorithm(AT) 1 method:limit cycle 2 AT cycle:3 b)self-tuning heating/cooling, except PID control motion Control Output a) Relay Output:250VAC 3A(with load )1a connectionelectrical:over 300000 times,rated load b) Voltage Output:0-12VDC(load resistance :over 600Ω) c) Current Output:4-20maDC(load resistance :over 600Ω) d) flow control tube briving tri non-sensitive zone er output:medium capacity driving.....e) flow control tube output:rated 0.5A(the ambient temperature is below 40oC)Temperature alarm Alarm:2 points(set separately)Alarm type:Deviation alarm(Upper limit ,lower limit)Process value input alarm(Upper limit ,lower limit )SV Input alarm(Upper limit ,lower limit )*Optional enginery (except set value alarm)Control Loop Burnout Alarm(LBA)LBA set time:0.1-200.0min* can not be 0.0minLBA non-sensitive zone :0-9999oC[*F ](TemperatureInput)0- measuring range (Voltage /Current Input)*If it is 0,LBA is not available.Heater burnout alarm(HBA)Input:Current picker Output (RKC appointed type CTL-6-P-N CTL-12-S56-10L-N)Scope of application : CTL-6-P-N 0-30ACTL-12-S56-10L-N 0-100AAlarm OutputRelay Output:250VAC 1A(with load)La joint#over 50000 times on and off.#Select ALM1 or ALM2 when it is LBA#when control loop burnout alarm is in use, another LBA is not available.Communication(SCI)Interface :EIA RS-485Communication agreement:ANSI X3.28(1976)2.5A4Communication method:2 wires, inter-coonection In-pahse start/stopcommunication speed:2400.4800.9600.19200BPSstart digital:1data bits:7 or 8check odd-evenstop digital:1 or 2Max joints:32 (address set 0-99)Else Power cut: no effort when it is under 20ms *Over 20ms, it will back to original statusData protection from power cutAmbient temperature:0-50oC[32-122F]Ambient humidity:45-85%RHInstallation :flush bondingWeight:170g...
CB Series RKC temperature controller